Tubular membrane I5
The I5 membranes are suitable for the filtration of liquids with a low concentration of non-dissolved material.
The internal diameter of the tubular membranes is 5 mm. The maximum pressure of the HyperFlux-I5 module is 800 kPa. In use at the tubular module type HyperFlux with potted tubular membranes.
| Membrane type | Membrane material | Molecular weight cut-off | max. Temp. [°C] | max. Pressure [kPa] | pH-range |
| 37.03 I5 | PES | 100 kD | 60 | 800 | 2 – 10 |
| 66.01 I5 | PVDF | 15 kD | 60 | 800 | 2 – 10 |